Home > Products > Oil/Gas Fired Boiler > SZS Double Drums Water Tube Boiler

SZS Double Drums Water Tube Boiler

Capacity: 6t/h-20t/h   4.2mw/h - 14mw/h

Pressure: 0.7Mpa-1.6Mpa

Fuel: Natural gas, Lpg, Light oil, Diesel, Heavy oil, Dual fuels. 

Share:
  • Product Description
  • Specification
  • Delivery
  • Introduction 

    SZS series boiler body is double-drum, horizontal with D-type combustion chamber, the furnace is on the right, and the convection tubes on the left, movable supports in the midst and both sides of the furnace are mixed into the bottom plate of the boiler body, making sure that the boiler is expanding toward both sides in the whole. The furnace has narrow pitch pipe membrane water cooling walls in the surrounding, the membrane water cooling wall on the left of the furnace is completely sealed from the convection tubes. Behind the convection tubes is the sparse staggered structure, at the front is the aligned structure. The smoke from the burning in the combustion chamber leaves from smoke output at the back part of the furnace, enters into the burnout chamber and convection tubes, and then into finned tube economizer and condenser, and finally into the chimney by the flue and finally into the air.  

     

    Advantages

    1. Manhole, inspection door

    Manholes are set at the front and back of the furnace as well as the above and bottom part, the inspection door is set at the hind part of the boiler, easy to open from check and cleaning.

    2. Reliable water cycling

    The high temperature part of the boiler body employs forced circulation, ensuring that all heating surfaces can be cooled properly and vaporization is prevented.

    3. Membrane structure

    ◎The full membrane wall structure type I layout

    ◎Steam drum, water drum convection bank from convection heating surface, and ensure boiler as a whole expand to both ends.

    ◎Combustion chamber using narrow spacing membrane water wall, with good air tightness, reducing heat losing, improving the thermal efficiency of the boiler.

    ◎The back of the convection bank area is sparse shift structure.The front of the convection bank area is sequnce structure.

    ◎Front and back wall of boiler body all using membrane structure, greatly increase the service life of the front and back wall, ensure the service life of the front and back wall more than 20 years.

    ◎Membrane wall on both sides of boiler furnace and the sealing between the drum all use comb board, to eliminate the used refractory concrete sealing result in condensate and gas leak problem.

    4. Furnace insulation

    Using high quality aluminum silicate fiber, then fire clay insulation, furnace temperature was controlled below 45°,effective control the heat loss.

    5. Combustion chamber

    Due to the combustion chamber adopts full membrane water wall structure, and by the micro positive pressure combustion, so without smoke issues. Working environment pollution-free.

    6. Installation devices

    Boiler is decorated with explosion door and flame detector, safe and reliable operation.

  • Steam boiler

    Item           Model          Unit   SZS6-1.25-Q.Y  SZS6-1.6-Q.Y  SZS6-2.5-Q.YSZS10-1.25-Q.Y  SZS10-1.6-Q.Y  SZS10-2.5-Q.YSZS20-1.25-Q.Y  SZS20-1.6-Q.Y  SZS20-2.5-Q.YSZS30-1.25-Q.Y  SZS30-1.6-Q.Y  SZS30-2.5-Q.YSZS40-1.25-Q.Y  SZS40-1.6-Q.Y  SZS40-2.5-Q.YSZS50-1.25-Q.Y  SZS50-1.6-Q.Y  SZS50-2.5-Q.Y
    Rated evaporation capacityt/h61020304050
    Rated working pressure Mpa1.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.51.25/1.6/2.5
    Rated steam temperature194/204/225194/204/225194/204/225194/204/225194/204/225194/204/225
    Designed heat efficiency%>98>98>98>98>98>98
    Available fuel
    Natural gas/biogas/coke gas/light oil/methanol/biodiesel etc
    Fuel
    consumption 
    Light oilkg/h3726201240186024803100
    Natural gasM³/h4327201440216028803600


    Hot water boiler with pressure

    Item                                    Model                                               Unit 

    SZS7-1.0/115/70-Q.YSZS10.5-1.0/115/70-Q.YSZS14-1.25/115/70-Q.YSZS17.5-1.25/115/70-Q.YSZS21-1.25/130/70-Q.Y
    Rated Thermal PowerMW710.51417.521
    Rated Outlet Water PressureMpa1.01.01.251.251.25
    Rated Outlet Water Temperature959595115115
    Rated Return Water Temperature7070707070
    Thermal Efficiency (Oil/Gas)%93.08
    91.56

    91.87

    92.713
    93.2191.2
    Water Volume2.63.36911.6
    Funel Temperature (Oil/Gas)119.68
    118.15
    143.88
    122.38

    127.81
    116.3160
    Fuel Consumption (Oil/Gas)Kg
    m³/h
    69.16
    81.55
    155.82
    155.82
    253.78
    301
    378.65
    449
    644.99
    764.99
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • WNS Single Drum Smoke Tube Boiler

  • DZL Single Drum Automatically Boiler

  • SZL Double Drums Automatically Boiler

  • YY(Q)W Horizontal Oil / Gas Boiler

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
* Name:
Mobile:
* E-mail:
* Area:
Application:
  • Food industry
  • Textile industry
  • Printing industry
  • Oils industry
  • Pharmaceutical industry
  • Power industry
  • Petroleum industry
  • Chemical industry
  • AAC production industry
  • Wood processing industry
  • Hotels industry
* Message:
*
Welcome to MOBILE SITE
contact us